Navien furnace error codes
74 codes (71 faults, 3 normal display and menu codes).
| Code | Meaning | Severity / type |
|---|---|---|
| 1 Flash | High limit switch open | Medium |
| 2 Flashes | Pressure switch open with inducer on | Medium |
| 3 Flashes | Pressure switch closed with inducer off | Medium |
| 4 Flashes | Control in 1 hour lockout | High |
| 5 Flashes | L1/Neutral polarity problem | High |
| 6 Flashes | Too many limit trips in one call for heat | High |
| 7 Flashes | Pressure switch cycle lockout | High |
| 8 Flashes | Lockout due to too many flame dropouts | High |
| 9 Flashes | Flash code 9 not used | Menu / mode display |
| 10 Flashes | Flame present with gas valve off | Critical |
| E003 00 | Ignition failure | High |
| E004 0 | False flame | Medium |
| E012 00 | Flame loss during combustion | High |
| E016 00 | Heat exchanger overheating | Critical |
| E030 02 | Abnormal exhaust gas temperature (lock out) | Critical |
| E031 00 | Burner overheating | Critical |
| E046 00 | Abnormal limit control operation on heat exchanger | Critical |
| E047 01 | Abnormal exhaust temperature sensor operation | Medium |
| E047 02 | Abnormal exhaust temperature sensor operation | Medium |
| E109 00 | Abnormal inducer fan operation | Medium |
| E205 01 | Abnormal supply water temperature sensor, lower limit | Medium |
| E205 02 | Abnormal supply water temperature sensor, upper limit | Medium |
| E218 01 | Abnormal return water temperature sensor, lower limit | Medium |
| E218 02 | Abnormal return water temperature sensor, upper limit | Medium |
| E238 01 | Abnormal recirculation pump operation | Medium |
| E238 02 | Abnormal recirculation pump operation | Medium |
| E302 00 | Low water level | Low |
| E311 00 | Abnormal water level sensor | Medium |
| E351 00 | Abnormal auto water fill | Medium |
| E360 00 | Abnormal cover opening | Medium |
| E515 01 | Abnormal WD-PSS1 status | High |
| E515 02 | Abnormal WD-PSS2 status | High |
| E515 03 | Abnormal MGV1 status | High |
| E515 04 | Abnormal MGV2 status | High |
| E515 09 | Abnormal fan control | High |
| E515 10 | Abnormal monitoring device status | High |
| E515 16 | Abnormal AWS feedback | High |
| E515 24 | Abnormal leakage input | High |
| E517 00 | Abnormal DIP switch settings | High |
| E593 00 | Abnormal front panel keys | Medium |
| E594 | Abnormal EEPROM operation | High |
| E594 00 | Abnormal EEPROM operation | High |
| E615 | Controller fault (sub codes 01, 03, 04, 05) | High |
| E615 01 | Abnormal overheat controller feedback | Critical |
| E615 03 | Abnormal flame signal input | Critical |
| E615 04 | Abnormal ADC reference voltage | Critical |
| E615 05 | Abnormal MCU | Critical |
| E740 | Abnormal outdoor temperature sensor (sub codes 01, 02) | Medium |
| E740 01, 02 | Abnormal outdoor temperature sensor operation | Medium |
| E762 | Vent pipe not detected by Vent Installation Detector (VID) | High |
| E762 00 | Improper vent pipe installation | Medium |
| E774 | External safety device on IN_1 stops the furnace | High |
| E774 00 | Abnormal external safety system operation 1 | Medium |
| E775 | External safety device on IN_2 stops the furnace (auto reset) | Medium |
| E775 00 | Abnormal external safety system operation 2 | Medium |
| E782 | Controller to front panel communication error | Medium |
| E782 00 | Controller to panel communication abnormal | Medium |
| E786 | Abnormal front control panel connection | Medium |
| E786 00 | Abnormal front control panel connection | Medium |
| E788 | Abnormal gas type setting | High |
| E788 00 | Abnormal gas type settings | High |
| E799 | Leak detected (sensor 00, water level 01) | Critical |
| E799 00 | Leak detected (sensor) | Critical |
| E799 01 | Leak detected (water level) | Critical |
| E805 | Abnormal supply air temperature sensor (sub codes 01, 02) | Medium |
| E810 | Abnormal circulator operation (inoperable), sub codes 00–09 | High |
| E811 | Abnormal circulator operation (inoperable) | High |
| E818 | Abnormal return air temperature sensor (sub codes 01, 02) | Medium |
| E822 | Overcooling of the air conditioning coil (evaporator coil) | Medium |
| E860 | IAQ replacement alerts (sub codes 01, 02, 03) | Normal status |
| E890 | Abnormal circulator communication | High |
| LED Flashing | Green LED flashing, high pressure switch not closed | Medium |
| LED ON | Red status LED on, normal operation | Normal status |
| LED Off | Red status LED off | High |
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.