Navien · Furnace
E003 00 Ignition failure
What the control is telling you
Ignition fails or no flame is detected. Possible causes are a clogged vent or blocked condensate drain.
Applies to: NPF Condensing Hydro-furnace
Likely causes
- Main gas supply closed
- Exhaust duct blocked or damaged
- Condensate drain clogged
- Propane tank low (propane installs)
Test and repair steps
- Check that the main gas supply is open.
- Check the exhaust duct for blockage or damage.
- Check that the condensate drain is clear.
- Check propane tank level and replace the tank if needed.
- If the furnace stays inoperable, contact Navien Technical Support.
Other codes on the same units
- E004 0 False flame
- E012 00 Flame loss during combustion
- E016 00 Heat exchanger overheating
- E030 02 Abnormal exhaust gas temperature (lock out)
- E031 00 Burner overheating
- E046 00 Abnormal limit control operation on heat exchanger
- E047 01 Abnormal exhaust temperature sensor operation
- E047 02 Abnormal exhaust temperature sensor operation
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: NPF Condensing Hydro-furnace installation and operation manual, p. 125. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.