Navien · Furnace

E788 Abnormal gas type setting

High severity NPF

What the control is telling you

The DIP switches for the gas type are not set correctly, or the gas type was changed without completing the conversion check.

Applies to: NPF700 series furnaces

Test and repair steps

  1. Check that the DIP switch 1 gas type setting matches the supply gas.
  2. After a propane conversion, run the Gas Type Check under the Start-Up Wizard and set it to Propane Gas to clear the error.

Other codes on the same units

  • E782 Controller to front panel communication error
  • E782 00 Controller to panel communication abnormal
  • E786 Abnormal front control panel connection
  • E786 00 Abnormal front control panel connection
  • E788 00 Abnormal gas type settings
  • E799 Leak detected (sensor 00, water level 01)
  • E799 00 Leak detected (sensor)
  • E799 01 Leak detected (water level)

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NPF Condensing Hydro-furnace installation and operation manual, p. 128 and p. 135. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.