E822 Overcooling of the air conditioning coil (evaporator coil)
What the control is telling you
The supply air temperature is abnormal, which points to overcooling of the evaporator coil.
Applies to: NPF700 series furnaces
Test and repair steps
- Check the condition of the air conditioning coil (evaporator coil).
- Check that the duct filter is clean.
- Check that the set cooling airflow suits the cooling capacity.
Other codes on the same units
- E799 00 Leak detected (sensor)
- E799 01 Leak detected (water level)
- E805 Abnormal supply air temperature sensor (sub codes 01, 02)
- E810 Abnormal circulator operation (inoperable), sub codes 00–09
- E811 Abnormal circulator operation (inoperable)
- E818 Abnormal return air temperature sensor (sub codes 01, 02)
- E860 IAQ replacement alerts (sub codes 01, 02, 03)
- E890 Abnormal circulator communication
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NPF Condensing Hydro-furnace installation and operation manual, p. 129. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.