Lennox · Furnace

Red LED slow flash (heartbeat) Normal - idle, continuous fan or cooling

Normal status Lennox EL195UHNE

What the display is showing

The red LED blinks slowly, about 1 second on and 1 second off, repeating. This heartbeat means the control is powered and healthy and the furnace is idle, running the fan continuously, or running a cooling call. No fault.

Applies to: EL195UHNE furnaces with ignition control 103217-03 or 107163-01 (red LED)

Settings for these units

Filter sizes (filter rack kits) · Lennox EL195UHNE

CabinetHorizontal end rackSide return rack
B width (040, 060)18 x 25 x 1 (kit 87L96)16 x 25 x 1 (kit 44J22)
C width (080, 100)20 x 25 x 1 (kit 87L97)16 x 25 x 1 (kit 44J22)

Filters are field supplied; check monthly.

100NE60C over 1800 cfm with single side return needs a 20 x 25 x 1 filter via return air base and transition.

Models that show this code

4 models in Lennox EL195UHNE

EL195UH040NE36BEL195UH060NE36BEL195UH080NE48CEL195UH100NE60C

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox EL195UHNE Unit Information Corp 1801-L1 (rev 04/2024), Table 4 (103217-03) / Table 5 (107163-01) diagnostic codes, p.8-10. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.