KeepRite air conditioner error codes

37 codes (27 faults, 10 normal display and menu codes), plus 1 settings tables.

CodeMeaningSeverity / type
1Comfort Alert 1 - long run timeMedium
2Comfort Alert 2 - system pressure tripHigh
3Comfort Alert 3 - short cyclingMedium
4Comfort Alert 4 - locked rotorHigh
5Comfort Alert 5 - open circuitHigh
6Comfort Alert 6 - open start circuitHigh
7Comfort Alert 7 - open run circuitHigh
9Comfort Alert 9 - low control voltageMedium
16Lost communication with wall controlMedium
25Model plug missing or invalidHigh
31High pressure switch openHigh
45Outdoor control board failureHigh
46Brown-out (low voltage)Medium
47No 230 V at the unitHigh
53Outdoor air temperature sensor faultMedium
55Outdoor coil sensor faultMedium
56Air and coil sensors disagreeMedium
71Low stage thermal cutoutHigh
72Compressor thermal cutout (two-stage: high stage)High
73Contactor stuck closedHigh
74No 230 V at compressorHigh
81Low stage thermal lockoutHigh
82Thermal lockout (two-stage: high stage)High
83Low pressure lockoutHigh
84High pressure lockoutHigh
Amber 1 flashRunning - cooling / low stage (normal)Normal status
Amber 2 flashesHigh stage running (normal)Normal status
Amber 5 flashesBrown-out protection turned off (user setting)Normal status
Amber 6 flashesBrown-out protection active (user setting)Normal status
Amber LED offStandby - no call (2-wire hookup or indoor unit unpowered)Normal status
Amber LED on solidStandby - no call (communicating)Normal status
Brown-out defeat toggleTurn 230 V brown-out protection off or onMenu / mode display
Green COMM LED offNo communication yetNormal status
Green COMM LED onCommunication with the system establishedNormal status
Green POWER LEDComfort Alert module has powerNormal status
Red TRIP LEDComfort Alert TRIP - Y call but compressor not runningHigh
TRIP + ALERT flashing togetherComfort Alert - control voltage too low to operateMedium

Settings and specs

Outdoor unit clearances

Clearances · KeepRite C4A3/CXA6 AC

LocationMinimum
Service end24 in. (610 mm)
Above unit48 in. (1219 mm)
One side6 in. (152 mm)
Other sides12 in. (305 mm)
Between units24 in. (610 mm); 18 in. (457 mm) with no overhang within 12 ft
Roof mount height above roof6 in. (152 mm)
Shrubs/fences from coil18 in. (457 mm)
  • Keep roof run-off and snow from falling on the unit.
  • Unit must be level within 2 degrees.

Source: KeepRite/ICP C4A3/H4A3/T4A3/CXA6 Installation Instructions 421 01 5103 05, Clearances / Unit Support p.2, Maintenance p.12

Models covered

*CA624*CA636*CA648*CA660*CA924*CA936*CA948*CA960*SA5*SA6C4A3CXA6

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.