KeepRite · Air conditioner
Amber 6 flashes Brown-out protection active (user setting)
What the display is showing
Six flashes, then a pause. Shows the 230 V brown-out protection is switched on, which is the factory state. It also appears while the brown-out defeat is being toggled.
Applies to: *CA/*CH two-stage communicating outdoor boards
Settings for these units
- Outdoor unit clearances · KeepRite C4A3/CXA6 AC
Models that show this code
8 models in KeepRite *CA/*CH Two-Stage Communicating
Other codes on the same units
- 82 Thermal lockout (two-stage: high stage)
- 83 Low pressure lockout
- 84 High pressure lockout
- Amber 1 flash Running - cooling / low stage (normal)
- Amber 2 flashes High stage running (normal)
- Amber 5 flashes Brown-out protection turned off (user setting)
- Amber LED on solid Standby - no call (communicating)
- Brown-out defeat toggle Turn 230 V brown-out protection off or on
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: KeepRite ICP split A-C + HP (R-410A & R-22) Application Guideline and Service Manual 421 08 5400 04, Table 17 p.59-60 and Brown-Out Protection Defeated, p.57. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.