Goodman · Heat pump

CoreSense solid yellow Solid yellow RUN - module powered, operating normally

Normal status Goodman/Amana R-32 GLZS/ALZSGoodman/Amana R-410A GSZ/ASZ/DSZ (ANZ/SSZ/VSZ)

What the display is showing

The CoreSense module on the compressor shows a steady yellow RUN light when it has power and sees normal operation, with no trip. Nothing to fix. A flashing yellow light is an alert and a red light is a trip or lockout.

Applies to: ASZ/DSZ/GSZ and GLZS/ALZS heat pumps with CoreSense

Models that show this code

122 models in Goodman/Amana R-32 GLZS/ALZS, Goodman/Amana R-410A GSZ/ASZ/DSZ (ANZ/SSZ/VSZ)

ALZS4BA**10AAALZS4NA**10AAALZS5BA**10AAANZ130181ANZ130241ANZ130301ANZ130361ANZ130421ANZ130481ANZ130601ANZ140181ANZ140241ANZ140301ANZ140361ANZ140421ANZ140481ANZ140491ANZ140601ASZ130181ASZ130241ASZ130301ASZ130361ASZ130421ASZ130481ASZ130601ASZ140181ASZ140241ASZ140301ASZ140361ASZ140381ASZ140421ASZ140481ASZ140491ASZ140601ASZ160181ASZ160241ASZ160301ASZ160361ASZ160421ASZ160481ASZ160601ASZ180361ASZ180481ASZ180601ASZH5***10DSZ160241DSZ160361DSZ160481DSZ160601DSZ180361DSZ180481DSZ180601GLZS4BA**10AAGLZS4MA**10AAGLZS5BA**10AAGSZ110903GSZ110904GSZ111203GSZ111204GSZ130181

Other codes on the same units

  • CoreSense 1 Yellow 1 flash - long run time (low side)
  • CoreSense 2 Pressure trip - yellow 2 flashes (red 2 = lockout)
  • CoreSense 3 Short cycling / pressure switch cycling - yellow 3 (red 3 = lockout)
  • CoreSense 4 Locked rotor - yellow 4 (red 4 = lockout)
  • CoreSense 5 Moderate run trip - yellow 5 (red 5 = lockout)
  • CoreSense 9 Red 9 flashes - PROT output overcurrent
  • CoreSense solid red Solid red TRIP - call present but compressor not running

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: GSX/GSZ service RS6200006r103, CoreSense Diagnostics Table p.76 and Quick Reference Table 1 p.78; R-32 GLXS/GLZS service RS6200301, CoreSense Diagnostics Table p.21. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.