Fujitsu · Heat pump
24 Connection unit number error
What the control is telling you
Too many or wrong number of indoor units / branch units connected. Indoor lamps: OPERATION (green) flashes 2x, TIMER (orange) flashes 4x, ECONOMY (green) flashes fast nonstop; wired remote shows 24.
Applies to: Fujitsu ductless heat pumps: Fujitsu ductless split/multi/VRF (general code list), Fujitsu wall-mounted 7-15 (NA ASU/AOU type), Fujitsu slim duct ARU 7-18 (LL type)
Likely causes
- Unit count outside the allowed range
- Address setup wrong
Test and repair steps
- Count connected indoor and branch units and compare with the system limits.
- Check address settings and cycle power.
Settings for these units
- Operating range and service space · Fujitsu multi-zone outdoor 18/24 type
Other codes on the same units
- 16 Peripheral unit / transmission PCB connection error
- 21 Address / refrigerant circuit setting error
- 22 Indoor unit capacity error
- 23 Combination error
- 26 Indoor unit address setting error
- 27 Primary / secondary unit setup error
- 29 Connection unit number error (wired remote system)
- 31 Power supply interruption error
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Fujitsu All Fujitsu split - multi - VRF (generic code list) codes.pdf - section error code table (indoor LED flashes); Fujitsu Wall-mounted 7-9-12-15 (North American trilingual, UTY-RNNUM remotes; e.g. ASU9-12-15 RLF1-RLS familie.pdf - section 14 Error codes; Fujitsu Slim duct AR07-09-12-14-18 (ARU-ARYG LL-type equivalent) installation P-N 9381858064.pdf - section 14 Error codes. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.