Water temperature fluctuates
What is going on
So you're getting hot water, then cold, then hot again, or it just never reaches the temperature you set. That's common with tankless heaters and it usually comes down to flow, scale or gas supply. When the flow sits right near the minimum the burner keeps turning on and off, and you feel it as a temperature swing. Scale on the heat exchanger and a gas line that can't keep up when other appliances run are the other usual suspects.
Likely causes
- Flow near the minimum activation flow, so the burner cycles
- Scale build-up in the heat exchanger
- Low or fluctuating gas pressure when other appliances run
- Recirculation or crossover issue mixing cold into the hot line
- Temperature set too low for the demand, or too many fixtures running at once
Check in this order
- Check the set temperature and the flow rate at the fixture, try one tap open fully
- Clean the inlet filter and flush the heat exchanger if scale is suspected, especially in hard water areas
- Measure gas pressure with several appliances running, a drop under load points to an undersized line
- Check for plumbing crossover and recirculation settings, a leaking mixing valve or single-handle faucet can do it
- Compare the demand with the unit's capacity at the incoming water temperature, winter water is much colder
- Turn off other fixtures and see if the swing stops, that tells you if it is a capacity issue
Applies to: Tankless water heaters
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.