All brands · Tankless water heater troubleshooting
No hot water
What is going on
Water runs, but it never warms up. Tankless units are fussy about flow, gas and power. Hot water shows up only when the flow is high enough, the burner lights and the heat exchanger can pass water. Look at the remote or display first, an error code saves a lot of time. No code usually points to low flow, a plugged inlet screen or a crossover.
Likely causes
- Flow below the unit's minimum activation flow
- Gas supply off or undersized gas line
- Clogged inlet water filter
- Plumbing crossover between hot and cold
- Unit in error or lockout, or no power
Check in this order
- Check the remote or display for an error code and look it up under Error Codes
- Open a hot tap fully and confirm flow is above the minimum activation flow, low flow means no ignition
- Clean the inlet water filter, shut isolation valves first and expect some water
- Confirm gas is on and check inlet gas pressure at full fire (gas work is for a licensed tech)
- Check for a crossover shut the cold inlet and see if water still flows from hot taps
- Verify power to the unit, outlet or switch and display lit
- If the unit fires and then shuts down, note the code and the burner behaviour before calling for service
Applies to: Tankless water heaters
More tankless water heater guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: General HVAC service practice — verify per model. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.