Rinnai · Tankless water heater troubleshooting

Checking PC board fuses and thermistors

What is going on

If your Rinnai is throwing board or temperature sensor codes, two things are worth testing before you buy a new PC board: the glass fuses and the thermistors. Both are cheap and both take a meter and a few minutes. The fuses protect the board, and the thermistors tell the board what the water temperature is, so a drifted sensor can make the heater act strangely even though nothing looks broken. Always kill the power before you pull anything.

Likely causes

  • Blown glass fuse on the PC board, from a short or surge on a connected load
  • Thermistor open, shorted or out of range, so the board reads the wrong water temperature
  • Corroded or loose thermistor connector giving an unstable resistance reading
  • Board problem that only shows up after the fuse and sensors have checked good

Check in this order

  1. Disconnect power first, then pull each of the two glass fuses on the PC board and test continuity. No continuity means the fuse is blown and must be replaced with the same rating.
  2. If a fuse blew, look for the reason before you power up again, such as a pinched wire or a seized pump or fan.
  3. Unplug the thermistor connector and measure on the 20 k range at the thermistor side, never with the plug connected to the board.
  4. Warm the sensor bulb in your fingers or warm water. Resistance should fall steadily.
  5. Cool it with ice. Resistance should rise. A reading that jumps around or does not move means the sensor is bad.
  6. Compare your readings with the typical temperature to resistance table for the sensor.
  7. Wiggle the connector while watching the meter to catch an intermittent contact.
  8. Replace the faulty part, reconnect, and run the unit to confirm the code is gone.

Applies to: SENSEI RX/CX (RX199i, RX180i, RX160i, RX130i, CX199i, CX160i, RXP199i, RXP160i, CXP199i, CXP160i)

More tankless water heater guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Rinnai SENSEI RX/CX technical guide U362-0875, Electrical Diagnostics. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.