Lifebreath · Hrv troubleshooting

Water in the bottom of the HRV

RNC

What is going on

Standing water inside the cabinet.

Likely causes

  • Drain pans plugged
  • Drain lines connected wrong
  • HRV not level
  • Drain lines blocked or kinked
  • Core not installed right

Check in this order

  1. Kill power at the HRV disconnect before opening the unit. Some units have more than one power feed.
  2. Check the drain line, spout and P-trap for blockage, mould or kinks.
  3. Flush the line with warm soapy water. Replace it if it is worn, bent or won't come clean.
  4. Check the unit is level.
  5. Pull the core and reinstall it bottom edge on the bottom support first, line it up with the other 3 supports, push on the sides, not the middle.

Applies to: Lifebreath RNC series HRV

More hrv guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Troubleshooting, p. 14; Maintenance Routine, p. 12-13. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.