Humidity too high, condensation on windows
What is going on
Indoor humidity stays high and windows sweat in the heating season.
Likely causes
- Dehumidistat set too high
- HRV not sized for a hot tub or indoor pool
- Occupant habits (clothes drying inside, wood stored inside, dryer venting inside)
- Moisture from an unvented or unheated crawl space
- Moisture staying in bathrooms and kitchen
- HRV speed too low
- Spring and fall shoulder season
Check in this order
- Lower the dehumidistat set point.
- Turn the HRV speed up.
- Ask the owner to keep pools and hot tubs covered when not in use.
- Look for clothes drying, firewood or a dryer venting inside. Move firewood outside.
- Check the crawl space. It needs venting and a vapour barrier on the floor.
- Some condensation on humid days in spring and fall is normal.
Applies to: Lifebreath RNC series HRV
More hrv guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Troubleshooting, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.