Lifebreath · technician tips

Lifebreath service menus, test modes and resets

8 tips for hrv: access codes, button combinations, test modes and the resets you need at the appliance.

Jump to: Button combinations (1) · Service & test modes (1) · Reset & cancel (3) · Settings shortcuts (1) · Other (2)

Button combinations

Key presses that open menus, show readouts or switch modes.

Lock or unlock the 99-DET01 timer

Hrv · RNC

Lockout stops the wall timer from calling high speed.

  1. Hold the select button 5 seconds to lock.
  2. Hold 5 seconds again to unlock.

Applies to: 99-DET01

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Timers - 99-DET01, p. 9. Written in our own words; check the manual for your exact model.

Service & test modes

Forced fan, low and high fire, test and diagnostic modes, error history and live data.

Self-test on every power-up

Hrv · RNC

Each time the HRV gets power it runs a self-test: it steps through the speeds and checks the damper motor, then goes back to the selected mode. Takes about 60 seconds. Don't mistake it for a fault.

  1. Wait about 60 seconds after power-up before judging operation.

Applies to: Lifebreath RNC series HRV

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Additional Information, p. 15. Written in our own words; check the manual for your exact model.

Reset & cancel

Clearing lockouts, service reminders and fault history; skipping purge or de-air programs.

Clear the service reminder

Hrv · RNC

Clears the service symbol on the DXPL02 after maintenance.

  1. Hold ON/OFF for 5 seconds.

Applies to: 99-DXPL02

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Digital Control DXPL02, p. 9. Written in our own words; check the manual for your exact model.

DXPL02 reset button defaults

Hrv · RNC

The RESET button on the DXPL02 wipes the fan, timer, mode and dehumidistat settings.

  1. Press RESET.
  2. Unit comes back on LOW speed, Ventilation mode, dehumidistat at 40%.

Applies to: 99-DXPL02

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Digital Control DXPL02, p. 9. Written in our own words; check the manual for your exact model.

Power reset re-enables the dehumidistat

Hrv · RNC

If the dehumidistat was turned off by the warm-weather auto disable, a power reset brings it back.

  1. Unplug the HRV for 30 seconds, then plug it back in.

Applies to: BC02, BC03, DXPL02

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), How the Dehumidistat Works, p. 4. Written in our own words; check the manual for your exact model.

Settings shortcuts

Where the useful parameters live and what they are set to from the factory.

DXPL02 20/40/60 high speed button

Hrv · RNC

Temporary high speed override on the DXPL02.

  1. Press once = 20 min, twice = 40 min, 3 times = 60 min.
  2. Press a 4th time to cancel.
  3. The unit goes back to its old speed when time runs out.

Applies to: 99-DXPL02

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Digital Control DXPL02, p. 8. Written in our own words; check the manual for your exact model.

Other

Everything else worth knowing at the appliance.

Core cleaning do's and don'ts

Hrv · RNC

Soak and rinse the core in warm soapy water only.

  1. No cleaning chemicals, bleach or chlorine.
  2. No pressure washer.
  3. No dishwasher.

Applies to: Lifebreath RNC series HRV

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Maintenance Routine, p. 12. Written in our own words; check the manual for your exact model.

Core sticks out about 1/8 in

Hrv · RNC

After reinstalling, the core can sit about 1/8 in (3 mm) proud of the cabinet. That is on purpose so the door seals tight on it.

  1. Do not force the core further in.

Applies to: Lifebreath RNC series HRV

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Maintenance Routine, p. 12. Written in our own words; check the manual for your exact model.

Same tips in your pocket

The HVACopedia app has these tips, every error code and the settings tables offline.

Open the app

For licensed technicians. Installer menus, test modes and access codes change settings that affect safety; only use them if you are trained on the appliance and understand the result. Gas, electrical and refrigerant work must be done by a qualified, licensed person, and the manufacturer’s manual for the exact model and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.