Lifebreath · Hrv troubleshooting
Supply air feels cold
What is going on
Fresh air coming in feels cold to the occupants in winter.
Likely causes
- Very cold outdoor temperature
- Furniture or closed doors stopping air from mixing
- Supply ducted into the furnace return with the furnace fan off
Check in this order
- Lower the HRV supply speed.
- Check that furniture and closed doors are not trapping the supply air in one spot.
- If the HRV supply goes into the furnace return, run the furnace fan on continuous so the air gets mixed and spread out.
Applies to: Lifebreath RNC series HRV
More hrv guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Troubleshooting, p. 14. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.