Poor airflow from HRV

RNC

What is going on

Weak supply or exhaust air at the grilles. Usually something plugged or closed.

Likely causes

  • 1/4 in (6 mm) bird screen on an outside hood plugged
  • Dirty filters
  • Core blocked
  • Grilles closed or blocked by furniture
  • Balancing dampers closed
  • Low supply voltage
  • Duct run too restrictive
  • Speed set too low on the control
  • Unit not balanced

Check in this order

  1. Kill power at the HRV disconnect before opening the unit. Some units have more than one power feed.
  2. Check both outside hoods first. Clear leaves, snow or frost off the mesh.
  3. Pull and wash the filters, then pull and wash the core.
  4. Walk the house and open any closed or blocked grilles.
  5. Check the balancing dampers are open and set.
  6. Turn the speed up on the wall control and see if flow comes back.
  7. Check the duct install for crushed or long flex runs.
  8. If still weak, have an electrician check supply voltage and rebalance the HRV airflows.

Applies to: Lifebreath RNC series HRV

More hrv guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Troubleshooting, p. 14. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.