Zero crossing detection error

Vitocal 100-S

What is going on

If the zero crossing signal interval is wrong for 240 seconds continuously, the unit stops and the LED shows the failure. The correct interval is 6 to 13 ms.

Likely causes

  • Zero crossing signal interval outside 6 to 13 ms

Check in this order

  1. Check the power supply waveform and wiring to the zero crossing input.
  2. Confirm the signal interval is between 6 and 13 ms.

Applies to: DLCURA outdoor unit

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCURA Service Manual, p. 18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.