Water connections and piping
What is going on
Support all piping on hangers so no load goes onto the unit. Flush the heating system before connecting, especially before tying the heat pump into an existing system. Ground loop connections use NPS straight thread and need gasketed fittings. Use an approved pipe sealant or Teflon tape on the other fittings. Do not exceed the listed pressures or temperatures, or the warranty is void.
Check in this order
- Flush the heating system thoroughly, especially before connecting to an existing system.
- Connect the ground loop return (A) and supply (B) using double O-ring fittings supplied in the field; remove the caps first.
- Connect the DHW tank supply (E) and tank return (F) using approved sealant or Teflon tape.
- Use two wrenches when tightening fittings onto the heat pump connectors: one holds the connector to stop twisting, the other tightens the fitting.
- Support all piping with hangers; do not support piping by the unit or its components.
- Install isolation valves so system components can be isolated.
- Make sure the condensate line (C) is connected.
Applies to: Vitocal 100-WA, all models
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: vitocal_100-wa_ap1t_ios.pdf, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.