Water around base of unit

Vitocal 100-WA

What is going on

Water collecting at the base of the unit.

Likely causes

  • Water leak
  • Condensate from water coil or accumulator
  • Condensation pan not draining
  • Air coil freezing

Check in this order

  1. Find and repair any water leak.
  2. Insulate the water coil and accumulator if they sweat.
  3. Check the pan for algae and blow out the condensate pipe restriction.
  4. Check for a dirty air filter or duct restriction if the air coil freezes.

Applies to: Vitocal 100-WA

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 52. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.