Viessmann · Heat pump troubleshooting

Thermostat installation and third-party requirements

Vitocal 100-WA

What is going on

Mount the thermostat to block drafts. Third-party thermostats must support heat pump operation.

Check in this order

  1. Mount the thermostat on foam tape to seal the wire penetration; silicone can also be used.
  2. Follow the thermostat instructions for programming in heat pump mode.
  3. Use two heat plus aux heat and two cool, 7-day programmable thermostat for third-party units.
  4. Wire Y2 for stage 2 heat or cool, B only on dual-speed systems, and E for strip heat if fitted.
  5. Leave E unwired if the system has no strip heat.

Applies to: Vitocal 100-WA terminal strip systems

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 26. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.