Temperature sensor resistance check

Vitocal 100-S

What is going on

Checks the outdoor unit temperature sensors (room T1, indoor coil T2, outdoor coil T3, outdoor ambient T4, compressor discharge T5). Compare the measured resistance against the sensor resistance table in the manual. That table is not on these pages.

Check in this order

  1. Turn off all power or disconnect all wires before starting.
  2. Let the compressor and coil return to normal temperature before touching them.
  3. Disconnect the temperature sensor from the PCB.
  4. Measure the sensor resistance with a multimeter.
  5. Compare the reading with the sensor resistance table for that temperature.
  6. Replace the sensor if the reading does not match.

Applies to: DLCSRB outdoor units, models 06 to 36

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCSRB Service Manual, p. 48. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.