Viessmann · Heat pump troubleshooting

Temperature sensor check

Vitocal IND-O

What is going on

Check a temperature sensor by its resistance. Sensors are: room temp (T1), indoor coil (T2), outdoor coil (T3), outdoor ambient (T4) and compressor discharge (T5).

Check in this order

  1. Turn off all power or disconnect all wires before working.
  2. Disconnect the temperature sensor from the PCB.
  3. Measure the sensor resistance with a multimeter.
  4. Compare the reading with the sensor resistance table in the disassembly section.
  5. Let the compressor and coil return to normal temperature before working on them.

Applies to: Room, indoor coil, outdoor coil, outdoor ambient and discharge sensors

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal IND-O DLFSOAH service instructions, p. 36. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.