Table 66 – 18K Heating, High Static Slim Duct: how to read the heating data
What is going on
Heating performance grid for the 18K D5CSRA with the high static slim duct indoor unit. Airflow blocks shown on these pages are 412 and 529 CFM. Outdoor dry bulb rows run from -22°F to 64.4°F. Capacity (BTU/hr) is in the first five columns and power input (kW) in the last five, at indoor dry bulb temperatures of 60.8, 68, 70, 71.6 and 75.2°F. The -22°F row is blank ('/'). The table continues beyond these pages.
Check in this order
- Select the airflow block that matches the indoor unit airflow in CFM.
- Find the outdoor dry bulb row for the actual outdoor temperature.
- Read total heating capacity (BTU/hr) from the first five columns for the indoor temperature.
- Read power input (kW) from the last five columns in the same row.
- Check the next manual page for any further airflow blocks before using the table.
Applies to: D5CSRA 18K heating, High Static Slim Duct indoor unit
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: D5CSRA Product Data, p. 176. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.