System Type B, Application B2 design requirements
What is going on
Primary/secondary multi-zone layout with two space heating zones and one DHW zone, controlled through the DHW-priority zone panel. The boiler has one priority and reset curve because the AHS is a single output.
Check in this order
- Pipe the system primary/secondary.
- Place the boiler downstream of the heat pump so high return temperatures do not shut the heat pump down when both run together.
- Size the zone circulators for the required flow.
- Provide space heating and DHW zone circulators (installer supplied). Add more zone panels for additional zones.
- Note that the boiler circulator ships loose and the heat pump circulator is installed in the heat pump manifold.
- Make sure all zones run safely at supply temperatures up to 149°F, or add mixing valves.
- If boiler reset is used, check that the DHW supply temperature curve is sufficient for DHW operation, or use a single boiler target temperature instead (confirm with ECOCalc).
- Set the boiler and heat pump controls using the boiler manual and heat pump page 11 navigation.
Applies to: System Type B, Application B2 (primary/secondary)
More heat pump guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: ECO HP Heat Pump Application Guide, p. 30. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.