Weil-McLain · Heat pump troubleshooting

Application A1: multi-zone space heating with DHW as zone

ECO HP

What is going on

Three space heating zones and one DHW zone run through the Unity 2.0 controlled boiler. DHW has priority, so space heating is disabled during a DHW call from the indirect tank. If the boiler runs with the heat pump, the boiler must be downstream of the heat pump to keep high water temperature away from the heat pump inlet. Piping must be primary/secondary.

Check in this order

  1. Pipe the boiler downstream of the ECO HP.
  2. Pipe the system as primary/secondary.
  3. Size the DHW circulator for the pressure drop through the indirect tank and piping; large indirect heaters may need different piping.
  4. Size the zone circulators for the required flow.
  5. For alternate wiring, use a DHW-priority zone panel such as the Thermostat Interface Unit.
  6. Note that ECO Tec boilers have an internal boiler circulator.
  7. The heat pump circulator is installed in the heat pump manifold and comes in the heat pump accessory box.
  8. Set the boiler controls per the boiler control table on page 20 and the heat pump controls per page 21; navigate the heat pump menu per page 11.

Applies to: System Type A1

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: ECO HP Heat Pump – Application Guide, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.