System Type A, Application A1: heat pump indoor unit wiring
What is going on
The heat pump indoor unit takes 120 V AC input on its relay board. Its outputs go to the Unity 2.0 AHD1 input for space heating and to the AHD2 input for DHW. The indoor unit pump is wired to the indoor unit board. Figure text is partly garbled, so verify terminal and wire colour labels against the wiring diagram on the unit before connecting.
Check in this order
- Connect 120 V AC power to the indoor unit input (L, N, PE).
- Wire the heating call output from the indoor unit to Unity 2.0 AHD1.
- Wire the DHW call output from the indoor unit to Unity 2.0 AHD2.
- Wire the indoor unit pump to its pump connector.
- Confirm the Class 2 low-voltage wiring is separated from line voltage.
Applies to: System Type A, Application A1 heat pump indoor unit
More heat pump guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: ECO HP Heat Pump – Application Guide, p. 18. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.