Viessmann · Heat pump troubleshooting

Size 36 top cover and front panel removal

Vitocal 100-S

What is going on

Removal sequence for the top cover and front panels on the size 36 outdoor unit.

Check in this order

  1. Turn off the air conditioner and the power breaker.
  2. Remove the 2 handle screws, then remove the handle.
  3. Remove the 4 top cover screws (two are under the handle), then remove the top cover.
  4. Remove the 2 screws of the front right panel, then remove the front right panel.
  5. Remove the 9 screws from the front panel, then remove the front panel.

Applies to: Size 36 DLCLRC outdoor unit

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCLRC Service Manual, p. 39. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.