Viessmann · Heat pump troubleshooting
Rooms are too cold
What is going on
Heating is not keeping rooms warm enough.
Likely causes
- Heat pump is switched off.
- Controller settings were changed or are incorrect.
- DHW heating is in progress.
- Display shows a Warning or Fault.
Check in this order
- Switch on the power switch.
- Switch on the main switch if fitted outside the mechanical room.
- Check the house fuse in the electrical switchboard.
- Check work program, heating curve, room temperature, time and the space heating time program.
- Enable additional electric heating for space heating if needed.
- Wait until DHW heating finishes, or reduce hot water draw or temporarily lower the normal DHW temperature.
- Read out and confirm the Warning or Fault.
- If needed, contact an Authorised Service Centre.
Applies to: Vitocal 100-AW AM2V
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 67. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.