Room temperature sensor location and wiring
What is going on
Place the room sensor in the main living room on an internal wall, away from heat sources and draughts.
Check in this order
- Mount on an internal wall in the main living room.
- Keep at least 5 ft (1.5 m) from the floor.
- Keep away from windows, doors, radiators and heat sources such as direct sun, a fireplace or a TV.
- Use two-wire cable up to 150 ft (50 m) long, 22 AWG (0.34 mm2).
Applies to: Vitocal 100-AW AM2V indoor unit
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V installation manual, p. 27. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.