Viessmann · Heat pump troubleshooting

Room or DHW frost protection in Standby or Summer

Vitocal 100-AW

What is going on

In Standby and Summer modes, if room temperature falls below 45°F (7°C) the central heating circuit is activated. If DHW temperature falls below 45°F (7°C) with frost protection enabled, DHW tank heating is enabled. The room function needs a room temperature sensor.

Likely causes

  • Room temperature below 45°F (7°C) in Standby or Summer mode
  • DHW temperature below 45°F (7°C) with frost protection enabled

Check in this order

  1. Confirm a room temperature sensor is connected if room frost protection is expected to work.
  2. Confirm frost protection is enabled for DHW if the tank must be held above 45°F (7°C).

Applies to: Standby and Summer modes

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 52. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.