Viessmann · Heat pump troubleshooting
Replacing the refrigerant leak detector
What is going on
Only use Viessmann-supplied replacement parts.
Check in this order
- Remove the front access panel (see Accessing the Heat Pump, p. 17).
- At the base of the leak detector, press the connector release tab and pull the connector downward to disconnect it.
- Remove the 2 top screws to release the leak detector mounting bracket.
- Remove the 2 screws securing the leak detector to the bracket.
- Remove the faulty leak detector and discard it.
- Install the new leak detector by reversing the steps above.
Applies to: Vitocal 100-WA refrigerant leak detector
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 61. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.