What is going on

Access and removal of the control board on the 18K model with 208/230V supply. Several sensor and valve connectors must be disconnected.

Check in this order

  1. Remove the screws and loosen the hooks, then open the electronic control box cover (5 screws and 2 hooks).
  2. Disconnect the fan motor connector from the electronic control board.
  3. Remove the compressor connector.
  4. Pull out the two blue wires connected to the four-way valve.
  5. Pull out the connectors of the condenser coil temperature sensor (T3), outdoor ambient temperature sensor (T4) and discharge temperature sensor (TP).
  6. Disconnect the electronic expansion valve wire.
  7. Remove the connector for the DR and reactor.
  8. Remove the electronic control board.

Applies to: DLCSRB 18K model, 208/230V

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCSRB Service Manual, p. 71. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.