Viessmann · Heat pump troubleshooting
Replace electronic control board, PCB 12K (115V)
What is going on
Access and removal of the control board on the 12K model with 115V supply.
Check in this order
- Disconnect the compressor connector and release the ground wire (1 screw).
- Pull the wires out of the electrical supporting plate and turn the electronic control assembly over.
- Remove the electronic installing box subassembly (4 hooks).
- Remove the board (2 hooks).
- Disconnect the connectors from the electronic control board.
- Remove the electronic control board (4 hooks).
Applies to: DLCSRB 12K model, 115V
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLCSRB Service Manual, p. 67. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.