Viessmann · Heat pump troubleshooting
Removing the access panels
What is going on
Lower access panel, top panel and display panel are removed in sequence. The display cable is long enough to swing the display panel aside. Front and side panels can all be removed for install and service work.
Check in this order
- Pull the lower access panel out from the handle to release the magnetic latch, then lift it up and out.
- Remove the two panel retaining screws at the bottom of the top panel.
- Slide the upper panel down and pull it out. Set the display panel aside by its cable, or disconnect the cable at the display if more room is needed.
- Reinstall in reverse order.
Applies to: Vitocal 100-WA
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: vitocal_100-wa_ap1t_ios.pdf, p. 17. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.