Viessmann · Heat pump troubleshooting

Remove main control board and fan capacitors (48K-58K electrical parts)

Vitocal 100-SDLCLRC

What is going on

Electrical parts removal for 48K to 58K sizes. Low and high pressure switch, T3 and T4 sensors connect to the IPM module. TP connects to the indoor unit.

Check in this order

  1. Remove the 2 screws and disconnect the power supply wires.
  2. Remove the 3 screws and disconnect the ground wires.
  3. Disconnect the wires connected to the main control board.
  4. Disconnect the wires between the main control board and the IPM module board.
  5. Remove the 4 screws, release the 6 hooks, and remove the main control board.
  6. Remove 1 screw per fan motor capacitor and remove the capacitors.

Applies to: 48K-58K

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCLRC service manual, p. 48. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.