Viessmann · Heat pump troubleshooting

Remove IPM module board and 24V board (48K-58K)

Vitocal 100-SDLCLRC

What is going on

Continues electrical parts removal. DC fan motors connect to the main control board. Compressor wires are removed here.

Check in this order

  1. Remove the 2 screws and disconnect the power supply wires.
  2. Remove the 3 screws and disconnect the wires connected to the compressor.
  3. Remove the 3 screws and remove the radiator.
  4. Disconnect the wires between the IPM module board and the main control board.
  5. Remove the 4 screws, release the 4 hooks, and remove the IPM module board.
  6. Remove the 1 screw, disconnect the wires, and remove the 24V board.

Applies to: 48K-58K

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCLRC service manual, p. 49. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.