Viessmann · Heat pump troubleshooting
Remove fan assembly and fan motor
What is going on
Remove the panel plate and disconnect the fan motor at the PCB before taking the fan motor apart.
Check in this order
- Remove the panel plate and disconnect the fan motor connection on the PCB.
- Remove the nut that holds the fan, using a spanner.
- Remove the fan.
- Remove the 4 fan motor screws.
- Remove the fan motor.
Applies to: DLCSRB outdoor units, all sizes shown in the manual
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-S DLCSRB service manual, p. 74. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.