Viessmann · Heat pump troubleshooting

Refrigerant leakage detection (cooling mode)

Vitocal 100-S

What is going on

Active only in COOLING mode. Protects the compressor from refrigerant leak or overload. Detects the case where the evaporator T2 coil temperature stays flat or changes very little while the compressor runs.

Likely causes

  • Refrigerant leak
  • Compressor overload

Check in this order

  1. Check T2 coil temperature using the point check function (press 04) while the compressor runs.
  2. Check refrigerant charge and look for leaks if T2 does not change.

Applies to: DLCURA system in cooling mode

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: DLCURA Service Manual, p. 18. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.