Viessmann · Heat pump troubleshooting

Refrigerant leak response

Vitocal 100-WA

What is going on

The unit contains flammable R-454B refrigerant (A2L). Treat any suspected leak as a fire and explosion hazard and clear the area before any work.

Likely causes

  • Damage to the refrigerant circuit or its lines
  • Escaping R-454B forming a flammable mixture with room air

Check in this order

  1. Ensure very good ventilation of the area.
  2. Keep smoking and naked flames away. Do not switch lights or electrical appliances on or off.
  3. Evacuate people from the danger zone.
  4. From a safe position, switch off power to all system components.
  5. Remove all ignition sources and tell the system user that no ignition source may enter the area during the repair.
  6. Have the repair carried out by a certified contractor.
  7. Recommission the system only after the repair is complete.

Applies to: Vitocal 100-WA, models AP1T 027020 to AP1T 077056

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: vitocal_100-wa_ap1t_ios.pdf, p. 6. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.