Qualification and work area checks before working on a flammable refrigerant system
What is going on
Only competent persons may break into the refrigerant circuit, open sealed components or open ventilated enclosures. Check the area before work starts.
Check in this order
- Confirm the person doing the work is competent for this task.
- Check the area with a suitable refrigerant detector before and during work.
- Keep a dry powder or CO2 extinguisher next to the charging area if hot work is planned.
- Remove ignition sources, including smoking, and post No Smoking signs.
- Make sure the area is open or well ventilated before breaking into the system, and keep ventilation running during the work.
- Brief everyone working nearby on the work being done. Avoid confined spaces.
Applies to: Vitocal 100-AW AM2V outdoor unit refrigerant circuit
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-AW AM2V installation, service and operating instructions, p. 8. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.