Pressure relief valve drips

Weil-McLain ECO HP

What is going on

Relief valve keeps leaking.

Likely causes

  • Dirt holding the relief valve seat open

Check in this order

  1. Lift the valve lever and listen for a clean snap shut.
  2. No snap, or it keeps running close the water inlet and outlet shut-offs and replace or service the valve.

Applies to: ECO HP 41/48/55 MBH indoor unit / hydro-box (IDU)

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Weil-McLain ECO HP Split Air-to-Water Heat Pump IDU Product Manual 550-100-586/0824, sec. 11.2 General symptoms, p.54. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.