Blank display at first start-up
What is going on
Nothing shows on the user interface on a new install.
Likely causes
- Wiring missing or wrong between power supply and unit, or unit and user interface
- PCB fuse blown
- E8/E0 at start-up: air in the system or water level too low
- E2 at start-up: user interface wiring
Check in this order
- Turn off power at the disconnect before opening the unit or touching any wiring.
- Check power wiring to the unit and the wire to the user interface.
- Check the PCB fuse.
- E8 or E0 on start-up purge air and fill the system to the minimum level.
- E2 check the wiring between the user interface and the unit.
Applies to: ECO HP 41/48/55 MBH indoor unit / hydro-box (IDU)
More heat pump guides
Related
Weil-McLain error codes · Weil-McLain parts · Weil-McLain tips · Calculators and reference tables
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Weil-McLain ECO HP IDU Product Manual 550-100-586/0824, Failure diagnosis at first installation, p.42. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.