Viessmann · Heat pump troubleshooting

Preparing the work area before refrigerant circuit work

Vitocal 100-AW

What is going on

Reduce fire and leak risk before opening the refrigerant circuit.

Check in this order

  1. Tell all maintenance staff and people nearby about the work.
  2. Close off the area around the heat pump.
  3. Check the surroundings for combustible materials and ignition sources, and remove them.
  4. Post no-smoking signs.
  5. Work outdoors or ventilate the area well before cooling-circuit, welding or soldering work.
  6. Keep ventilation running at all times.
  7. Have a CO2 or powder fire extinguisher available when charging refrigerant or doing welding or soldering.

Applies to: R32 refrigerant circuit work

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 89. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.