Viessmann · Heat pump troubleshooting
Poor cooling performance
What is going on
Room does not cool well.
Likely causes
- Temperature setting is higher than the room temperature
- Heat exchanger on the indoor or outdoor unit is dirty
- Air filter is dirty
- Air inlet or outlet of either unit is blocked
- Doors or windows are open
- Sunlight is adding excessive heat
- Too many heat sources in the room (people, computers, electronics)
- Low refrigerant from a leak or long-term use
Check in this order
- Lower the temperature setting.
- Clean the affected heat exchanger.
- Remove the filter and clean it per the instructions.
- Turn the unit off, remove the obstruction, and turn it back on.
- Close all doors and windows while the unit runs.
- Close windows and curtains during high heat or bright sun.
- Reduce the number of heat sources in the room.
- Check for leaks, re-seal if needed, and top off the refrigerant.
Applies to: Cooling mode
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal IND-F DLFSFBH operating instructions, p. 17. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.