Routine tasks from the periodic maintenance table. Tasks marked with a dagger must be done by qualified service personnel, per the installation manual. Increase air filter cleaning in dusty areas.
Check in this order
- Indoor unit clean the air filter.
- Indoor unit replace the carbon filter.
- Indoor unit change the remote control batteries.
- Outdoor unit clean the outdoor coil from the outside.
- Outdoor unit (qualified service only) clean the outdoor coil from the inside.
- Outdoor unit (qualified service only) blow air over electric parts.
- Outdoor unit (qualified service only) check electrical connection tightness.
- Outdoor unit (qualified service only) clean the fan wheel.
- Outdoor unit (qualified service only) check fan tightening.
- Outdoor unit (qualified service only) clean the drain pans.
Applies to: Indoor and outdoor units, all intervals
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal IND-F DLFSFBH operating instructions, p. 16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.