Viessmann · Heat pump troubleshooting

Periodic maintenance (indoor and outdoor unit tasks)

Vitocal IND-F

What is going on

Routine tasks from the periodic maintenance table. Tasks marked with a dagger must be done by qualified service personnel, per the installation manual. Increase air filter cleaning in dusty areas.

Check in this order

  1. Indoor unit clean the air filter.
  2. Indoor unit replace the carbon filter.
  3. Indoor unit change the remote control batteries.
  4. Outdoor unit clean the outdoor coil from the outside.
  5. Outdoor unit (qualified service only) clean the outdoor coil from the inside.
  6. Outdoor unit (qualified service only) blow air over electric parts.
  7. Outdoor unit (qualified service only) check electrical connection tightness.
  8. Outdoor unit (qualified service only) clean the fan wheel.
  9. Outdoor unit (qualified service only) check fan tightening.
  10. Outdoor unit (qualified service only) clean the drain pans.

Applies to: Indoor and outdoor units, all intervals

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal IND-F DLFSFBH operating instructions, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.