Outdoor unit panel removal, size 18K (208/230V)
What is going on
Order of panel removal for the 18K outdoor unit. Photos are for reference and may differ from the actual unit.
Check in this order
- Turn off the air conditioner and the power breaker.
- Remove the handle screw (1) and take off the handle.
- Remove the top cover screws (3); one is under the handle. Lift off the top cover.
- Remove the water collecting cover screws (2) and take off the water collecting cover.
- Remove the front panel screws 7 screws on on/off models, 9 screws on inverter models. Take off the front panel.
- Remove the right panel screws (6) and take off the right panel.
Applies to: DLCSRB size 18K (208/230V)
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Viessmann DLCSRB service manual, p. 59-61. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.