Viessmann · Heat pump troubleshooting
Outdoor unit 18K high heat and 24K standard heat - outer panel disassembly
What is going on
Disassembly of the outdoor unit cover, front panel and right panel. Front panel screw count depends on model type.
Check in this order
- Turn off the air conditioner and the power breaker.
- Remove the handle screw (1), then remove the handle.
- Remove the top cover screws (3), then remove the top cover. One of the screws is located under the handle.
- Remove the water collecting cover screws (2), then remove the water collecting cover.
- Remove the front panel screws and then remove the front panel. Use 7 screws on on/off models or 9 screws on inverter models.
- Remove the right panel screws (6), then remove the right panel.
Applies to: Outdoor unit sizes 18K high heat and 24K standard heat
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLCURA Service Manual, p. 57-59 of 84. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.