Viessmann · Heat pump troubleshooting

Open loop well water piping and strainer

Vitocal 100-WA

What is going on

Open loop installs need a well of adequate capacity and good water quality. Do not use pond or lake water directly through the unit. PVC or CPVC may only be used for condensate lines, never on ground loop connections.

Check in this order

  1. Install a 18-20 mesh strainer in an easy-to-service location, with isolation valves so the system can be isolated for cleaning.
  2. Replace an undersized strainer with a larger 18-20 mesh unit if the well carries heavy debris.
  3. Route discharge water to an open discharge well, creek, pond or other point of use, with no restrictions and no leaks.
  4. Do not connect discharge directly to a sprinkler.
  5. Protect discharge tubing from freezing.
  6. Check local code requirements for discharge water.

Applies to: Open loop systems

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-WA technical data manual, p. 16. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.