Viessmann · Heat pump troubleshooting

Noisy operation

Vitocal 100-WA

What is going on

Unit makes unusual noise.

Likely causes

  • Defective fan motor
  • Defective compressor mounts
  • Defective compressor (internal damage)
  • Refrigerant line vibrating
  • Loose blower wheel
  • Foreign material in blower housing
  • Duct leak or loose duct
  • Excessive water pressure on well (thumping)
  • Duct work vibrating

Check in this order

  1. Repair or replace the fan motor.
  2. Replace compressor mounts.
  3. Replace the compressor if internally damaged.
  4. Reposition and secure the refrigerant line.
  5. Realign and tighten the blower wheel.
  6. Clean the blower housing.
  7. Repair and secure ductwork; install flex connectors on supply and return.
  8. Install a 25 lb pressure reducer on the well water supply line if pressure is excessive.

Applies to: Vitocal 100-WA

More heat pump guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 52. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.