Viessmann · Heat pump troubleshooting
Noisy operation
What is going on
Unit makes unusual noise.
Likely causes
- Defective fan motor
- Defective compressor mounts
- Defective compressor (internal damage)
- Refrigerant line vibrating
- Loose blower wheel
- Foreign material in blower housing
- Duct leak or loose duct
- Excessive water pressure on well (thumping)
- Duct work vibrating
Check in this order
- Repair or replace the fan motor.
- Replace compressor mounts.
- Replace the compressor if internally damaged.
- Reposition and secure the refrigerant line.
- Realign and tighten the blower wheel.
- Clean the blower housing.
- Repair and secure ductwork; install flex connectors on supply and return.
- Install a 25 lb pressure reducer on the well water supply line if pressure is excessive.
Applies to: Vitocal 100-WA
More heat pump guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: Vitocal 100-WA Installation, Service and Operating Instructions, p. 52. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.